| General characteristics |
| Photometric room minimum dimensions (LxWxH) in m |
2×1,5 |
2×1,5 |
2,5×2,5×2,6 |
3x3x2,9 |
| Devices under test characteristics |
| Maximum dimensions (LxWxH) in m |
1x1x1 |
1x1x1 |
0.5×0.5×0.5 |
2x2x2 |
| Maximum weight in kg |
30 |
30 |
30 |
70 |
| Measured parameters basic setting |
| Gamma angles standard resolution |
1° |
1° |
1° |
1° |
| C plans resolution (min) |
45° |
45° |
0.1° |
0.1° |
| C plans resolution (max) |
360° |
360° |
360° |
360° |
| Measured parameters basic setting |
|
Absolute photometric measurement
The function is applicable to any type of light fixture in any position (export in EULUMDAT or IESNA formats).
|
√ |
√ |
√ |
√ |
|
Relative photometric measurement
The function is applicable to any type of light fixture in any position (export in EULUMDAT or IESNA formats).
|
√ |
√ |
√ |
√ |
|
Luminous flux measurement
The function is applicable to any type of light fixture in any position (export in EULUMDAT or IESNA formats).
|
√ |
√ |
√ |
√ |
|
Symmetrizability of the results
Possibility of symmetrizing the photometric measurement data as a function of light body symmetry axis.
|
√ |
√ |
√ |
√ |
|
Extrapolation of measured data to multiple size instruments
Possibility of generating files .ldt (.ies) for luminairese with length n x l (n = 1, 2, 3, …) from the measurements of a l long luminaire.
|
√ |
√ |
√ |
√ |
| Optional functions (may be added in any moment) |
| Gonio-spectroradiometric function |
|
√ |
√ |
√ |
| Gonio-colorimetric function |
√ |
√ |
√ |
√ |
| Spectral irradiance (µW* cm-2 * nm-1) |
|
√ |
√ |
√ |
| X, Y, Z tristimolous values and X1, X2 components of X |
|
√ |
√ |
√ |
| Chromatic coordinates x, y (CIE1931 colour space) |
|
√ |
√ |
√ |
| Chromatic coordinates u’, v’ (CIELUV colour space) |
√ |
√ |
√ |
√ |
| Correlated color temperature (CCT) |
√ |
√ |
√ |
√ |
| Chromatic rendering index (CRI) |
√ |
√ |
√ |
√ |
| Test Color Samples (TCS) from CIE document |
|
√ |
√ |
√ |
| Rendering index evaluation |
|
√ |
√ |
√ |
| Chromatic difference (DC) |
|
√ |
√ |
√ |
| Fidelity Index |
|
√ |
√ |
√ |
| Gamut Area Index (GAI) |
|
√ |
√ |
√ |
| Duv |
|
√ |
√ |
√ |
| Full Width at Half Maximum (FWHM) |
|
√ |
√ |
√ |
| Peak wavelength |
|
√ |
√ |
√ |
| Main wavelength |
|
√ |
√ |
√ |
| Complementary wavelength |
|
√ |
√ |
√ |
| Purity |
|
√ |
√ |
√ |
| Television Lighting Consistency Index (TLCI) |
|
√ |
√ |
√ |
| Check the stability |
√ |
√ |
√ |
√ |
| Smoothing function |
√ |
√ |
√ |
√ |
| Customized reports |
√ |
√ |
√ |
√ |